CVE-2024-7908

Aug. 18, 2024, 5:15 p.m.

Received
CVE has been recently published to the CVE List and has been received by the NVD.

Products

TOTOLINK EX1200L

  • 9.3.5u.6146_B20201023

Source

cna@vuldb.com

Tags

CVE-2024-7908 details

Published : Aug. 18, 2024, 5:15 p.m.
Last Modified : Aug. 18, 2024, 5:15 p.m.

Description

A vulnerability, which was classified as critical, was found in TOTOLINK EX1200L 9.3.5u.6146_B20201023. Affected is the function setDefResponse of the file /www/cgi-bin/cstecgi.cgi. The manipulation of the argument IpAddress leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS Score

1 2 3 4 5 6 7 8.8 9 10

Weakness

Weakness Name Description
CWE-121 Stack-based Buffer Overflow A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVSS Data

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

Base Score

8.8

Exploitability Score

2.8

Impact Score

5.9

Base Severity

HIGH

This website uses the NVD API, but is not approved or certified by it.