CVE-2024-10313
Oct. 25, 2024, 12:56 p.m.
Tags
CVSS Score
Product(s) Impacted
SpiderControl SCADA PC HMI Editor
Description
iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.
Weaknesses
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.
CWE ID: 22Date
Published: Oct. 24, 2024, 6:15 p.m.
Last Modified: Oct. 25, 2024, 12:56 p.m.
Status : Awaiting Analysis
CVE has been recently published to the CVE List and has been received by the NVD.
More infoSource
ics-cert@hq.dhs.gov
CVSS Data
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
LOW
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
Base Score
Exploitability Score
Impact Score
Base Severity
HIGHCVSS Vector String
The CVSS vector string provides an in-depth view of the vulnerability metrics.
View Vector StringCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H