CVE-2023-39464

May 3, 2024, 12:50 p.m.

CVSS Score

7.2 / 10

Product(s) Impacted

Triangle MicroWorks SCADA Data Gateway

Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService

Description

Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.

Weaknesses

Date

Published: May 3, 2024, 3:15 a.m.

Last Modified: May 3, 2024, 12:50 p.m.

Status : Awaiting Analysis

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

zdi-disclosures@trendmicro.com

CVSS Data

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

HIGH

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

Base Score
7.2
Exploitability Score
Impact Score
Base Severity
HIGH
CVSS Vector String

The CVSS vector string provides an in-depth view of the vulnerability metrics.

View Vector String

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

References