Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Weaknesses
Date
Published: May 3, 2024, 3:15 a.m.
Last Modified: May 3, 2024, 12:50 p.m.
Status : Awaiting Analysis
CVE has been recently published to the CVE List and has been received by the NVD.
More infoSource
zdi-disclosures@trendmicro.com
CVSS Data
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
Base Score
Exploitability Score
Impact Score
Base Severity
HIGHCVSS Vector String
The CVSS vector string provides an in-depth view of the vulnerability metrics.
View Vector StringCVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H