CVE-2026-24032

April 14, 2026, 9:16 a.m.

6.9
Medium

Description

A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3 with UMC). The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. (ZDI-CAN-27564)

Product(s) Impacted

Vendor Product Versions
Siemens
  • Sinec Nms
  • <4.0

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-347
Improper Verification of Cryptographic Signature
The product does not verify, or incorrectly verifies, the cryptographic signature for data.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a siemens sinec_nms <4.0 sp3 / / / / / /

CVSS Score

6.9 / 10

CVSS Data - 4.0

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Attack Requirements: NONE
  • Privileges Required: NONE
  • User Interaction: NONE
  • Scope:
  • Confidentiality Impact: LOW
  • Integrity Impact: LOW
  • Availability Impact: LOW
  • Exploit Maturity: NOT_DEFINED
  • CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X