CVE-2025-36463

Nov. 18, 2025, 2:06 p.m.

7.3
High

Description

Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 4 (`WBIO_USH_ADD_RECORD`) and with an invalid `SendBufferSize`.

Product(s) Impacted

Product Versions
controlvault3
  • <5.15.14.19
controlvault3_plus
  • <6.2.36.47

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-805
Buffer Access with Incorrect Length Value
The product uses a sequential operation to read or write a buffer, but it uses an incorrect length value that causes it to access memory that is outside of the bounds of the buffer.

CVSS Score

7.3 / 10

CVSS Data - 3.1

  • Attack Vector: LOCAL
  • Attack Complexity: LOW
  • Privileges Required: LOW
  • Scope: UNCHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: HIGH
  • Availability Impact: HIGH
  • CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

    View Vector String

Timeline

Published: Nov. 17, 2025, 11:15 p.m.
Last Modified: Nov. 18, 2025, 2:06 p.m.

Status : Awaiting Analysis

CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

More info

Source

talos-cna@cisco.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.