CVE-2025-27493

March 11, 2025, 10:15 a.m.

8.2
High

Description

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.

Product(s) Impacted

Vendor Product Versions
Siemens
  • Sipass Integrated Ac5102
  • Sipass Integrated Acc-ap
  • *
  • *

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-20
Improper Input Validation
The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a siemens sipass_integrated_ac5102 / / / / / / / /
a siemens sipass_integrated_acc-ap / / / / / / / /

CVSS Score

8.2 / 10

CVSS Data - 3.1

  • Attack Vector: LOCAL
  • Attack Complexity: LOW
  • Privileges Required: HIGH
  • Scope: CHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: HIGH
  • Availability Impact: HIGH
  • CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

    View Vector String

Timeline

Published: March 11, 2025, 10:15 a.m.
Last Modified: March 11, 2025, 10:15 a.m.

Status : Awaiting Analysis

CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

More info

Source

productcert@siemens.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.