CVE-2025-23085
Feb. 25, 2025, 1:15 p.m.
5.3
Medium
Description
A memory leak could occur when a remote peer abruptly closes the socket without sending a GOAWAY notification. Additionally, if an invalid header was detected by nghttp2, causing the connection to be terminated by the peer, the same leak was triggered. This flaw could lead to increased memory consumption and potential denial of service under certain conditions.
This vulnerability affects HTTP/2 Server users on Node.js v18.x, v20.x, v22.x and v23.x.
Product(s) Impacted
| Product | Versions |
|---|---|
| Node.js |
|
Weaknesses
Common security weaknesses mapped to this vulnerability.
CWE-401
Missing Release of Memory after Effective Lifetime
The product does not sufficiently track and release allocated memory after it has been used, which slowly consumes remaining memory.
Tags
CVSS Score
CVSS Data - 3.0
- Attack Vector: NETWORK
- Attack Complexity: LOW
- Privileges Required: NONE
- Scope: UNCHANGED
- Confidentiality Impact: NONE
- Integrity Impact: NONE
- Availability Impact: LOW
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Timeline
Published: Feb. 7, 2025, 7:15 a.m.
Last Modified: Feb. 25, 2025, 1:15 p.m.
Last Modified: Feb. 25, 2025, 1:15 p.m.
Status : Awaiting Analysis
CVE has been recently published to the CVE List and has been received by the NVD.