CVE-2025-13036

June 16, 2026, 3:26 p.m.

9.2
Critical

Description

An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token.

Product(s) Impacted

Vendor Product Versions
Rockwell Automation
  • Factorytalk Historian Site Edition
  • *

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-362
Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
The product contains a code sequence that can run concurrently with other code, and the code sequence requires temporary, exclusive access to a shared resource, but a timing window exists in which the shared resource can be modified by another code sequence that is operating concurrently.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a rockwell_automation factorytalk_historian_site_edition / / / / / / / /

CVSS Score

9.2 / 10

CVSS Data - 4.0

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Attack Requirements: PRESENT
  • Privileges Required: NONE
  • User Interaction: NONE
  • Scope:
  • Confidentiality Impact: HIGH
  • Integrity Impact: HIGH
  • Availability Impact: LOW
  • Exploit Maturity: NOT_DEFINED
  • CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

    View Vector String

Timeline

Published: June 16, 2026, 3:16 p.m.
Last Modified: June 16, 2026, 3:26 p.m.

Status : Awaiting Analysis

CVE has been recently published to the CVE List and has been received by the NVD.

More info

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.