CVE-2024-8957

Oct. 1, 2024, 5:49 p.m.

9.8
Critical

Description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

Product(s) Impacted

Vendor Product Versions
Ptzoptics
  • Pt30x-sdi Firmware
  • Pt30x-sdi
  • Pt30x-ndi-xx-g2 Firmware
  • Pt30x-ndi-xx-g2
  • *
  • -
  • *
  • -

Weaknesses

CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.

*CPE(s)

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
o ptzoptics pt30x-sdi_firmware / / / / / / / /
h ptzoptics pt30x-sdi - / / / / / / /
o ptzoptics pt30x-ndi-xx-g2_firmware / / / / / / / /
h ptzoptics pt30x-ndi-xx-g2 - / / / / / / /

CVSS Score

9.8 / 10

CVSS Data

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: NONE
  • Scope: UNCHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: HIGH
  • Availability Impact: HIGH
  • View Vector String

    CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Date

  • Published: Sept. 17, 2024, 9:15 p.m.
  • Last Modified: Oct. 1, 2024, 5:49 p.m.

Status : Analyzed

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

disclosure@vulncheck.com