CVE-2024-6918 details
Published : Aug. 20, 2024, 1:15 p.m.
Last Modified : Aug. 20, 2024, 3:44 p.m.
Last Modified : Aug. 20, 2024, 3:44 p.m.
Description
CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP.
CVSS Score
1 | 2 | 3 | 4 | 5 | 6 | 7.5 | 8 | 9 | 10 |
---|
Weakness
Weakness | Name | Description |
---|---|---|
CWE-120 | Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') | The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow. |
CVSS Data
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
Base Score
7.5
Exploitability Score
3.9
Impact Score
3.6
Base Severity
HIGH
Vector String : CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H