CVE-2024-56336

March 11, 2025, 10:15 a.m.

9.8
Critical

Description

A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.

Product(s) Impacted

Vendor Product Versions
Siemens
  • Sinamics S200
  • *

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-287
Improper Authentication
When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a siemens sinamics_s200 / / / / / / / /

CVSS Score

9.8 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: NONE
  • Scope: UNCHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: HIGH
  • Availability Impact: HIGH
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

    View Vector String

Timeline

Published: March 11, 2025, 10:15 a.m.
Last Modified: March 11, 2025, 10:15 a.m.

Status : Awaiting Analysis

CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

More info

Source

productcert@siemens.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.