CVE-2024-52285

March 11, 2025, 10:15 a.m.

5.3
Medium

Description

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data.

Product(s) Impacted

Vendor Product Versions
Siemens
  • Sipass Integrated Ac5102
  • Sipass Integrated Acc Ap
  • *
  • *

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-306
Missing Authentication for Critical Function
The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a siemens sipass_integrated_ac5102 / / / / / / / /
a siemens sipass_integrated_acc_ap / / / / / / / /

CVSS Score

5.3 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: NONE
  • Scope: UNCHANGED
  • Confidentiality Impact: LOW
  • Integrity Impact: NONE
  • Availability Impact: NONE
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

    View Vector String

Timeline

Published: March 11, 2025, 10:15 a.m.
Last Modified: March 11, 2025, 10:15 a.m.

Status : Awaiting Analysis

CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

More info

Source

productcert@siemens.com