CVE-2024-47562
Oct. 11, 2024, 8:04 p.m.
Tags
CVSS Score
Products Impacted
Vendor | Product | Versions |
---|---|---|
siemens |
|
|
Description
A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command. This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.
Weaknesses
CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
CWE ID: 77Date
Published: Oct. 8, 2024, 9:15 a.m.
Last Modified: Oct. 11, 2024, 8:04 p.m.
Status : Analyzed
CVE has been recently published to the CVE List and has been received by the NVD.
More infoSource
productcert@siemens.com
CPEs
Type | Vendor | Product | Version | Update | Edition | Language | Software Edition | Target Software | Target Hardware | Other Information |
---|---|---|---|---|---|---|---|---|---|---|
a | siemens | sinec_security_monitor | / | / | / | / | / | / | / | / |
CVSS Data
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
LOW
Scope
CHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
Base Score
Exploitability Score
Impact Score
Base Severity
HIGHCVSS Vector String
The CVSS vector string provides an in-depth view of the vulnerability metrics.
View Vector StringCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H