CVE-2024-47553

Oct. 11, 2024, 8:04 p.m.

CVSS Score

9.9 / 10

Products Impacted

Vendor Product Versions
siemens
  • sinec_security_monitor
  • *

Description

A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ```ssmctl-client``` command. This could allow an authenticated, lowly privileged remote attacker to execute arbitrary code with root privileges on the underlying OS.

Weaknesses

CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')

The product constructs a string for a command to be executed by a separate component in another control sphere, but it does not properly delimit the intended arguments, options, or switches within that command string.

CWE ID: 88

Date

Published: Oct. 8, 2024, 9:15 a.m.

Last Modified: Oct. 11, 2024, 8:04 p.m.

Status : Analyzed

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

productcert@siemens.com

CPEs

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a siemens sinec_security_monitor / / / / / / / /

CVSS Data

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

Base Score
9.9
Exploitability Score
3.1
Impact Score
6.0
Base Severity
CRITICAL
CVSS Vector String

The CVSS vector string provides an in-depth view of the vulnerability metrics.

View Vector String

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

References

https://cert-portal.siemens.com/ productcert@siemens.com