CVE-2024-47553

Oct. 11, 2024, 8:04 p.m.

9.9
Critical

Description

A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ```ssmctl-client``` command. This could allow an authenticated, lowly privileged remote attacker to execute arbitrary code with root privileges on the underlying OS.

Product(s) Impacted

Vendor Product Versions
Siemens
  • Sinec Security Monitor
  • *

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
The product constructs a string for a command to be executed by a separate component in another control sphere, but it does not properly delimit the intended arguments, options, or switches within that command string.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
a siemens sinec_security_monitor / / / / / / / /

CVSS Score

9.9 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: LOW
  • Scope: CHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: HIGH
  • Availability Impact: HIGH
  • CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

    View Vector String

Timeline

Published: Oct. 8, 2024, 9:15 a.m.
Last Modified: Oct. 11, 2024, 8:04 p.m.

Status : Analyzed

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

productcert@siemens.com