Description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.

Product(s) Impacted

Product Versions
SINEC INS
  • All versions < V1.0 SP2 Update 3

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-125
Out-of-bounds Read
The product reads data past the end, or before the beginning, of the intended buffer.
CWE-400
Uncontrolled Resource Consumption
The product does not properly control the allocation and maintenance of a limited resource, thereby enabling an actor to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.

CVSS Score

5.3 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: NONE
  • Scope: UNCHANGED
  • Confidentiality Impact: NONE
  • Integrity Impact: NONE
  • Availability Impact: LOW
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

    View Vector String

Timeline

Published: Nov. 12, 2024, 1:15 p.m.
Last Modified: Nov. 12, 2024, 3:35 p.m.

Status : Awaiting Analysis

CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

More info

Source

productcert@siemens.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.