Products
Tenda W9
- 1.0.0.7(4456)
Source
cna@vuldb.com
Tags
CVE-2024-4243 details
Published : April 26, 2024, 10:15 p.m.
Last Modified : April 26, 2024, 10:15 p.m.
Last Modified : April 26, 2024, 10:15 p.m.
Description
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS Score
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8.8 | 9 | 10 |
---|
Weakness
Weakness | Name | Description |
---|
CVSS Data
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
LOW
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
Base Score
8.8
Exploitability Score
Impact Score
Base Severity
HIGH
Vector String : CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
References
URL | Source |
---|---|
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formwrlSSIDset.md | cna@vuldb.com |
https://vuldb.com/?ctiid.262134 | cna@vuldb.com |
https://vuldb.com/?id.262134 | cna@vuldb.com |
https://vuldb.com/?submit.319825 | cna@vuldb.com |