CVE-2024-39876

July 9, 2024, 6:19 p.m.

4.0
Low

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.

Product(s) Impacted

Product Versions
SINEMA Remote Connect Server
  • < V3.2 SP1

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-770
Allocation of Resources Without Limits or Throttling
The product allocates a reusable resource or group of resources on behalf of an actor without imposing any restrictions on the size or number of resources that can be allocated, in violation of the intended security policy for that actor.

CVSS Score

4.0 / 10

CVSS Data - 3.1

  • Attack Vector: LOCAL
  • Attack Complexity: LOW
  • Privileges Required: NONE
  • Scope: UNCHANGED
  • Confidentiality Impact: NONE
  • Integrity Impact: NONE
  • Availability Impact: LOW
  • CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

    View Vector String

Timeline

Published: July 9, 2024, 12:15 p.m.
Last Modified: July 9, 2024, 6:19 p.m.

Status : Awaiting Analysis

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

productcert@siemens.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.