CVE-2024-39873

July 9, 2024, 6:19 p.m.

7.5
High

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

Product(s) Impacted

Product Versions
SINEMA Remote Connect Server
  • < V3.2 SP1

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-307
Improper Restriction of Excessive Authentication Attempts
The product does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it more susceptible to brute force attacks.

CVSS Score

7.5 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: NONE
  • Scope: UNCHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: NONE
  • Availability Impact: NONE
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

    View Vector String

Timeline

Published: July 9, 2024, 12:15 p.m.
Last Modified: July 9, 2024, 6:19 p.m.

Status : Awaiting Analysis

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

productcert@siemens.com