CVE-2024-39571

July 9, 2024, 6:19 p.m.

CVSS Score

8.8 / 10

Product(s) Impacted

SINEMA Remote Connect Server

  • < V3.2 HF1

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.

Weaknesses

CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

CWE ID: 77

Date

Published: July 9, 2024, 12:15 p.m.

Last Modified: July 9, 2024, 6:19 p.m.

Status : Awaiting Analysis

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

productcert@siemens.com

CVSS Data

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

Base Score
8.8
Exploitability Score
2.8
Impact Score
5.9
Base Severity
HIGH
CVSS Vector String

The CVSS vector string provides an in-depth view of the vulnerability metrics.

View Vector String

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H