CVE-2024-36140

Nov. 15, 2024, 10:53 p.m.

6.8
Medium

Description

A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to stored cross-site scripting (XSS) attacks. This could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges than the attacker.

Product(s) Impacted

Vendor Product Versions
Siemens
  • Ozw672 Firmware
  • Ozw672
  • Ozw772 Firmware
  • Ozw772
  • *
  • -
  • *
  • -

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

*CPE(s)

Affected systems and software identified for this CVE.

Type Vendor Product Version Update Edition Language Software Edition Target Software Target Hardware Other Information
o siemens ozw672_firmware / / / / / / / /
h siemens ozw672 - / / / / / / /
o siemens ozw772_firmware / / / / / / / /
h siemens ozw772 - / / / / / / /

CVSS Score

6.8 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: LOW
  • Scope: CHANGED
  • Confidentiality Impact: NONE
  • Integrity Impact: HIGH
  • Availability Impact: NONE
  • CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N

    View Vector String

Timeline

Published: Nov. 12, 2024, 1:15 p.m.
Last Modified: Nov. 15, 2024, 10:53 p.m.

Status : Analyzed

CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

More info

Source

productcert@siemens.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.