CVE-2023-47802

June 28, 2024, 10:27 a.m.

Awaiting Analysis
CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.

Products

Synology Camera Firmware

  • before 1.0.7-0298

Source

security@synology.com

Tags

CVE-2023-47802 details

Published : June 28, 2024, 6:15 a.m.
Last Modified : June 28, 2024, 10:27 a.m.

Description

A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the IP block functionality. This allows remote authenticated users with administrator privileges to execute arbitrary commands via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.7-0298 may be affected: BC500 and TC500.

CVSS Score

1 2 3 4 5 6 7.2 8 9 10

Weakness

Weakness Name Description
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.

CVSS Data

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

HIGH

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

Base Score

7.2

Exploitability Score

1.2

Impact Score

5.9

Base Severity

HIGH