CVE-2021-42718

Jan. 24, 2025, 3:15 p.m.

4.9
Medium

Description

Information Disclosure in API in Replicated Replicated Classic versions prior to 2.53.1 on all platforms allows authenticated users with Admin Console access to retrieve sensitive data, including application secrets, via accessing container definitions with environment variables through the Admin Console API on port 8800. This CVE was originally reserved in 2021 and later publicly disclosed by Replicated on their website on 21 October 2021. However, it mistakenly remained in the Reserved But Public (RBP) status with the CVE Numbering Authority (CNA). Please note that this product reached its end of life on 31 December 2024. Publishing this CVE with the CNA was required to comply with CNA rules, despite the fact that the issue was disclosed and fixed four years ago, and the affected product is no longer supported as of 2024. Summary of VulnerabilityThis advisory discloses a low severity security vulnerability in the versions of Replicated Classic listed above (“Affected Replicated Classic Versions”) DescriptionReplicated Classic versions prior to 2.53.1 have an authenticated API from the Replicated Admin Console that may expose sensitive data including application secrets, depending on how the application manifests are written. A user with valid credentials and access to the Admin Console port (8800) on the Replicated Classic server can retrieve container definitions including environment variables which may contain passwords and other secrets depending on how the application is configured. This data is shared over authenticated sessions to the Admin Console only, and was never displayed or used in the application processing. To remediate this issue, we removed the sensitive data from the API, sending only the data to the Admin Console that was needed. TimelineThis issue was discovered during a security review on 16 September 2021. Patched versions were released on 23 September 2021. This advisory was published on 21 October 2021. The CVE Numbering Authority (CNA) notified Replicated on 23 January 2025 that the CVE was still in Reserved But Public (RBP) status. Upon discovering the oversight in updating the status to published with the CNA, Replicated submitted the updated report on the same day, 23 January 2025.

Product(s) Impacted

Product Versions
Replicated Classic
  • ['before 2.53.1']

Weaknesses

Common security weaknesses mapped to this vulnerability.

CWE-922
Insecure Storage of Sensitive Information
The product stores sensitive information without properly limiting read or write access by unauthorized actors.

CVSS Score

4.9 / 10

CVSS Data - 3.1

  • Attack Vector: NETWORK
  • Attack Complexity: LOW
  • Privileges Required: HIGH
  • Scope: UNCHANGED
  • Confidentiality Impact: HIGH
  • Integrity Impact: NONE
  • Availability Impact: NONE
  • CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N

    View Vector String

Timeline

Published: Jan. 23, 2025, 11:15 p.m.
Last Modified: Jan. 24, 2025, 3:15 p.m.

Status : Awaiting Analysis

CVE has been recently published to the CVE List and has been received by the NVD.

More info

Source

security@replicated.com

*Disclaimer: Some vulnerabilities do not have an associated CPE. To enhance the data, we use AI to infer CPEs based on CVE details. This is an automated process and might not always be accurate.